OneTaq® Hot Start Quick-Load® 2X Master Mix with Standard Buffer
Product informationCode | Name | Size | Quantity | Price | |
---|---|---|---|---|---|
M0488S |
OneTaq Hot Start Quick-Load 2X Master Mix, Standard Buffer |
100 rxns ( 2 X ) | - | Unavailable in your region | |
M0488L |
OneTaq Hot Start Quick-Load 2X Master Mix, Standard Buffer |
500 rxns ( 2 X ) | - | Unavailable in your region |
OneTaq® Hot Start Quick-Load® 2X Master Mix with Standard Buffer
Product Introduction
The ONE polymerase for your endpoint PCR needs
OneTaq DNA Polymerase is an optimized blend of Taq and Deep Vent® DNA polymerases for use with routine and difficult PCR experiments.
- Unique hot start formulation eliminates nonspecific amplification and does not require a separate activation step
- Obtain high yields across a wide range of AT / GC content
- Offered with inert tracking dyes for easy and direct loading of PCR products onto gels
Catalog # | Size | Concentration |
---|---|---|
M0488S | 100.0 reactions (50.0 µl) | 2 X |
M0488L | 500.0 reactions (50.0 µl) | 2 X |
- Product Information
- Protocols, Manuals & Usage
- Tools & Resources
- FAQs & Troubleshooting
- Citations & Technical Literature
- Quality, Safety & Legal
- Other Products You May Be Interested In
Product Information
Description
OneTaq® Hot Start Quick-Load® 2X Master Mix with Standard Buffer is an optimized, ready-to-use blend of Taq and Deep Vent® DNA Polymerases combined with an aptamer-based inhibitor. This enzyme blend is ideally suited to routine PCR applications from a variety of templates, including pure DNA solutions, bacterial colonies and cDNA products. The 3´→5´ exonuclease activity of Deep Vent DNA Polymerase increases the fidelity and robust amplification of Taq DNA Polymerase (1). The hot start nature of the enzyme offers convenience with decreased interference from primer dimers and secondary products. The convenient Quick-Load master mix formulation contains dNTPs, MgCl2, buffer components and stabilizers as well as two commonly used tracking dyes for DNA gels. On a 1% agarose gel in 1X TBE, Xylene Cyanol FF migrates at ~4 kb and Tartrazine migrates at ~10 bp. Both dyes are present in concentrations that do not mask co-migrating DNA bands.
Product Source
An E. coli strain that carries the Taq DNA Polymerase gene from Thermus aquaticus YT-1 and an E. coli strain that carries the Deep Vent® DNA Polymerase gene from Pyrococcus species GB-D.- This product is related to the following categories:
- OneTaq® DNA Polymerases Products,
- Taq DNA Polymerase Products,
- Master Mixes Products,
- This product can be used in the following applications:
- Hot Start PCR,
- Multiplex PCR,
- Specialty PCR,
- Routine PCR, PCR
Reagents Supplied
Reagents Supplied
The following reagents are supplied with this product:
NEB # | Component Name | Component # | Stored at (°C) | Amount | Concentration | |
---|---|---|---|---|---|---|
Properties & Usage
1X Master Mix Composition
20 mM Tris-HCl
1X Tartrazine
25 units/ml OneTaq Hot Start DNA Polymerase
22 mM KCl
22 mM NH4Cl
1.8 mM MgCl2
5% Glycerol
0.06% IGEPAL® CA-630
0.05% Tween® 20
0.2 mM dNTPs
1X Xylene Cyanol
pH 8.9 @ 25°C
Heat Inactivation
NoUnit Assay Conditions
1X ThermoPol® Reaction Buffer, 200 µM dNTPs including [3H]-dTTP and 15 nM primed M13 DNA.Application Features
- High Sensitivity PCR
- High Throughput PCR
- Routine PCR
- AT-rich PCR
- Colony PCR
- Long PCR (up to ~6 kb genomic)
Related Products
Companion Products
Product Notes
- Product specifications for individual components in the OneTaq Hot Start Quick-Load 2X Master Mix with Standard Buffer are available separately.
- OneTaq Hot Start Quick-Load 2X Master Mix with Standard Buffer is stable for fifteen freeze-thaw cycles when stored at -20°C
- OneTaq Hot Start Quick-Load 2X Master Mix with Standard Buffer is also stable for one month at 4°C, so for frequent use, an aliquot may be kept at 4°C.
References
- Barnes, W.M. (1994). Proc. Natl. Acad. Sci. USA. 91, 2216-2220.
- Saiki, R.K. et al. (1985). Science. 230, 1350-1354.
- Powell, L.M. et al. (1987). Cell. 50, 831-840.
- Sun, Y., Hegamyer, G. and Colburn, N. (1993). Biotechniques. 15, 372-374.
- Sarkar, G., Kapelner, S. and Sommer, S.S. (1990). Nucleic Acids Res.. 18, 7465.
Protocols, Manuals & Usage
Protocols
Usage & Guidelines
Application Notes
Tools & Resources
Selection Charts
Web Tools
FAQs & Troubleshooting
FAQs
- What ends will my PCR products have?
- What are Hot Start and WarmStart® polymerases and when would I use them?
- How should I determine the appropriate annealing temperature for my reaction?
- What should the final primer concentration be in my PCR?
- What are the properties of this polymerase (fidelity, product ends, max amplicon, modified base incorporation, etc.)?
- What are the stability and storage requirements for NEB's Taq and OneTaq DNA Polymerases?
- Can Taq/OneTaq® DNA Polymerases be used for nick translation?
- How can I optimize my PCR when using Taq DNA Polymerase?
Troubleshooting
Tech Tips
Citations & Technical Literature
Citations
Additional Citations
Quality, Safety & Legal
Quality Assurance Statement
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.Specifications
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]Certificate Of Analysis
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]- M0488S_L_v1_0261706
- M0488S_L_v1_0271712
- M0488L_v1_10010188
- M0488L_v1_10014338
- M0488S_v1_10014213
- M0488L_v1_10023417
- M0488S_v1_10025327
- M0488L_v1_10032767
- M0488S_v1_10032763
- M0488S_v1_10035736
- M0488L_v1_10036835
- M0488S_v1_10038922
- M0488L_v1_10043251
- M0488S_v1_10042490
- M0488L_v1_10046280
- M0488S_v1_10046281
- M0488S_v1_10050539
- M0488L_v1_10048824
- M0488S_v1_10050308
- M0488L_v1_10054096
- M0488S_v1_10055861
- M0488L_v1_10057997
- M0488S_v1_10062112
- M0488L_v1_10063719
- M0488S_v2_10065735
- M0488L_v2_10072551
- M0488L_v2_10073016
- M0488S_v2_10073015
- M0488L_v2_10076946
- M0488S_v2_10076944
- M0488L_v2_10088611
- M0488S_v2_10084996
- M0488L_v2_10091532
- M0488L_v2_10095820
- M0488S_v2_10095819
- M0488L_v2_10102699
- M0488S_v2_10102700
- M0488S_v2_10109850
- M0488S_v2_10115508
- M0488L_v2_10112847
- M0488L_v2_10120340
- M0488S_v2_10120992
- M0488S_v2_10125230
- M0488L_v2_10127976
- M0488S_v2_10131781
- M0488L_v2_10132255
- M0488S_v2_10135955
- M0488L_v2_10140941
- M0488S_v2_10146695
- M0488L_v2_10146688
- M0488S_v2_10147933
- M0488L_v2_10153688
- M0488S_v2_10157241
- M0488L_v2_10157240
- M0488S_v2_10160639
- M0488L_v2_10161571
- M0488L_v2_10165613
- M0488S_v2_10164563
- M0488L_v2_10170530
- M0488S_v2_10172273
- M0488L_v2_10174294
- M0488L_v2_10179200
- M0488S_v2_10184717
- M0488L_v2_10184718
- M0488L_v2_10202493
- M0488S_v2_10203801
- M0488L_v2_10207808
- M0488S_v2_10208498
- M0488L_v2_10215699
- M0488S_v2_10221848
- M0488L_v2_10221847
- M0488L_v2_10231829
- M0488S_v2_10231828
- M0488L_v2_10244220
- M0488S_v2_10244225
- M0488L_v2_10250250
- M0488S_v2_10256528
- M0488L_v2_10263581
- M0488S_v2_10267525
Safety DataSheets
The following is a list of Safety Data Sheet (SDS) that apply to this product to help you use it safely.OneTaq® Hot Start Quick-Load® 2X Master Mix with Standard Buffer
Legal and Disclaimers
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
Licenses
Nucleic acid-based aptamers for use with thermophilic DNA polymerases are licensed exclusively by New England Biolabs, Inc. from SomaLogic, Inc. New England Biolabs, Inc. gives the Buyer/User a non-exclusive license to use the OneTaq® Hot Start Quick-Load® 2X Master Mix with Standard Buffer for Research Use Only (RUO). Commercial use of this product may require a license from New England Biolabs, Inc. For additional information or to inquire about commercial use, please contact busdev@neb.com.Trademarks
NEW ENGLAND BIOLABS®, ONETAQ®, QUICK-LOAD® and THERMOPOL® are registered trademarks of New England Biolabs, Inc.
DEEP VENT® is a trademark of New England Biolabs, INC.
IGEPAL® is a registered trademark of Rhodia Operations.
TWEEN® is a registered trademark of Uniqema Americas LLC.
Other Products You May Be Interested In
The supporting documents available for this product can be downloaded below.