NEBNext® Ultra™ II FS DNA PCR-free Library Prep Kit for Illumina®
Product informationCode | Name | Size | Quantity | Price | |
---|---|---|---|---|---|
E7430S |
NEBNext Ultra II FS DNA PCR-Free Library Prep Kit for Illumina |
24 rxns | - | Unavailable in your region | |
E7430L |
NEBNext Ultra II FS DNA PCR-Free Library Prep Kit for Illumina |
96 rxns | - | Unavailable in your region |
NEBNext® Ultra™ II FS DNA PCR-free Library Prep Kit for Illumina®
Product Introduction
Don’t be biased! The NEBNext Ultra II FS DNA PCR-free Library Prep Kit for Illumina offers an amplification-free workflow for DNA-seq based on the streamlined and reliable Ultra II FS workflow. Starting with as little as 50 ng of DNA, get the high-quality, high-yield libraries that you need without PCR bias.
- Includes NEBNext FS (Fragmentation System) enzymatic fragmentation reagents
- Perform fragmentation, end repair and dA-tailing with a single enzyme mix
- Save time with an optimized PCR-free workflow, reduced hands-on time and automation compatibility
- Generate high quality libraries without an amplification step using inputs from 50 ng to 500 ng intact DNA
- Benefit from improved library uniformity
- Use with the NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 1) or other Illumina-compatible index adaptors with 3′ single T overhang
For convenience, a version of this kit is available with SPRIselect beads.
Note: For sheared DNA, we recommend the NEBNext Ultra II DNA PCR-free Library Prep Kit for Illumina.
Catalog # | Size | Concentration |
---|---|---|
E7430S | 24.0 reactions | |
E7430L | 96.0 reactions |
- Product Information
- Protocols, Manuals & Usage
- FAQs & Troubleshooting
- Citations & Technical Literature
- Quality, Safety & Legal
- Other Products You May Be Interested In
Product Information
Description
The NEBNext Ultra II FS DNA PCR-free Library Prep Kit contains the enzymes and buffers required to convert a broad range of intact DNA input amounts into libraries for next-generation sequencing on the Illumina platform, all without an amplification step. The fast, user-friendly workflow includes reliable enzymatic DNA fragmentation, requires minimal hands-on time, resulting in excellent library yields and GC coverage without requiring PCR.
Advantages
- Enjoy flexible input amounts from 50 ng to 500 ng of intact DNA
- Experience reliable fragmentation with a single protocol, regardless of DNA input amount or GC content
- Perform fragmentation, end repair and dA-tailing with a single enzyme mix
- Get more of what you need with reliably high library yields
- Prepare PCR-free libraries with a broad range of sample types
- Save time with streamlined workflows, reduced hands-on time, and automation compatibility
- Use with the NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors DNA Set 1) (NEB #E7395) or other Illumina-compatible index adaptors with a 3’ single T overhang
A separate version of the NEBNext Ultra II FS DNA PCR-free Library Prep Kit is available with sample purification beads.

B. Libraries of 150-200 bp inserts were prepared using the enzyme-based fragmentation kits NEBNext Ultra II FS DNA PCR-free and Roche Sequencing Kapa HyperPlus PCR-free library prep kits without size selection. NEBNext Unique Dual Index UMI Adaptors DNA Set 1 and Kapa Dual-Indexed Adaptors were used for the NEBNext and Kapa kits, respectively, following manufacturers' recommendations.

- This product is related to the following categories:
- DNA Library Prep for Illumina,
- Automation for NEBNext® NGS Library Prep Products,
- Next Generation Sequencing Library Preparation Products,
Kit Components
Kit Components
The following reagents are supplied with this product:
Properties & Usage
Related Products
Companion Products
Protocols, Manuals & Usage
Protocols
Manuals
FAQs & Troubleshooting
FAQs
- What is the main application of the NEBNext Ultra II FS DNA PCR-free Library Prep Kit?
- What additional reagents do I need to complete the Ultra II FS DNA PCR-free workflow?
- Why is DTT included in the Ultra II FS DNA PCR-free kit?
- Can degraded samples be used for Ultra II FS DNA PCR-free library prep?
- What type of and how much starting material do I need when preparing libraries with the NEBNext Ultra II FS DNA PCR-free Library Prep Kit?
- When preparing samples using the NEBNext Ultra II FS DNA PCR-free Library Prep Kit, can my input DNA be in an EDTA-containing solution?
- What do I do if I see a precipitate in the Ultra II FS Reaction Buffer?
- Do I really need to vortex the Ultra II FS Enzyme Mix?
- Following the Fragmentation and End Prep steps of the NEBNext Ultra II FS PCR-free workflow, can the reactions be kept at 4˚C?
- The ligation reaction is very viscous. What will happen if it is not mixed properly?
- Which NEBNext Oligos can be used with NEBNext Ultra II FS DNA PCR-free Library Prep Kit?
- Following the Adaptor Ligation step, can the reactions be kept at 4˚C?
- Can I use the NEBNext Ultra II FS DNA PCR-free Library Prep Kit for bisulfite conversion or EM-seq™ workflows?
- Can I use the NEBNext Ultra II FS DNA PCR-free Library Prep Kit to prepare libraries for sequencing on Ion Torrent sequencing instruments?
- How do I quantify my PCR-free libraries?
- Can I assess PCR-free library quality on a BioAnalyzer and/or TapeStation?
- Can I use this NEBNext PCR-free kit with adaptors from vendors other than NEB?
Citations & Technical Literature
Citations
Additional Citations
Quality, Safety & Legal
Quality Assurance Statement
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.Specifications
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]Certificate Of Analysis
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]- E7430G_v0_10128536
- E7430S_v0_10128542
- E7430L_v0_10129074
- E7430L_v1_10146808
- E7430L_v1_10152853
- E7430S_v1_10155818
- E7430L_v1_10160964
- E7430L_v1_10144483
- E7430S_v1_10165408
- E7430G_v1_10165308
- E7430S_v1_10166956
- E7430L_v1_10172220
- E7430S_v1_10165736
- E7430L_v1_10165743
- E7430G_v1_10176306
- E7430L_v1_10174793
- E7430S_v1_10174786
- E7430L_v1_10187702
- E7430S_v1_10187226
- E7430G_v1_10198476
- E7430L_v1_10205814
- E7430S_v1_10205570
- E7430G_v1_10219368
- E7430L_v1_10187233
- E7430S_v1_10209579
- E7430G_v1_10209588
- E7430L_v1_10209576
- E7430G_v1_10231211
- E7430L_v1_10242284
- E7430S_v1_10235997
- E7430L_v1_10236003
- E7430G_v1_10235994
- E7430L_v1_10263053
- E7430S_v1_10257789
- E7430L_v1_10257793
- E7430G_v1_10257974
- E7430L_v1_10270585
- E7430S_v1_10270581
Safety DataSheets
The following is a list of Safety Data Sheet (SDS) that apply to this product to help you use it safely.NEBNext® Ultra™ II FS Enzyme Mix
NEBNext® Ultra™ II FS Reaction Buffer
NEBNext® Ligation Enhancer
NEBNext® Ultra™ II Ligation Master Mix
TE Buffer (1X)
DTT
Legal and Disclaimers
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
The supporting documents available for this product can be downloaded below.