NEBNext® Single Cell/Low Input cDNA Synthesis & Amplification Module
Product informationCode | Name | Size | Quantity | Price | |
---|---|---|---|---|---|
E6421S |
NEBNext Single Cell/Low Input cDNA Synthesis & Amplification Module |
24 rxns | - | Unavailable in your region | |
E6421L |
NEBNext Single Cell/Low Input cDNA Synthesis & Amplification Module |
96 rxns | - | Unavailable in your region |
NEBNext® Single Cell/Low Input cDNA Synthesis & Amplification Module
Product Introduction
How low can you go?
NEBNext® is now available for single cell and ultra-low RNA inputs!
This unique cDNA synthesis and amplification workflow meets the demand for a highly sensitive, yet robust method that consistently ultimately enables generation of high quality sequencing data from single cell or ultra-low input RNA.
- Generate the highest yields from single cells, or as little as 2 pg - 200 ng RNA
- Experience unmatched detection of low abundance transcripts
- Rely on consistent transcript detection for a wide range of input amounts and sample types
- Observe uniform transcript coverage, regardless of input amount or sample type
- Use with a variety of RNA inputs, including cultured or primary cells, or total RNA
- Save time with a fast, streamlined workflow, minimal handling steps and hands-on time
Please note that this module contains only reagents for cDNA synthesis and amplification. The NEBNext Single Cell/Low Input RNA Library Prep Kit for Illumina® (NEB #E6420) includes reagents for DNA library construction.
Catalog # | Size | Concentration |
---|---|---|
E6421S | 24.0 reactions | |
E6421L | 96.0 reactions |
- Product Information
- Protocols, Manuals & Usage
- FAQs & Troubleshooting
- Citations & Technical Literature
- Quality, Safety & Legal
- Other Products You May Be Interested In
Product Information
Description
The NEBNext® Single Cell/Low Input cDNA Synthesis & Amplification Module uses a template switching method to generate full length cDNAs directly from single cells or 2 pg – 200 ng RNA. This unique workflow enables generation of high quality sequencing data from a broad range of inputs, and superior transcript detection, while providing reliably consistent performance.
Features:
- The highest yields from single cells, or 2 pg - 200 ng RNA
- Input can be cultured or primary cells, or total RNA
- Single-tube protocol from cell lysis to cDNA
- Fast, streamlined, automation-friendly workflow, with minimal handling steps and hands-on time
Download extensive performance data in our technical note.
View extensive performance data in our technical note.
- This product is related to the following categories:
Reagents Supplied
Reagents Supplied
The following reagents are supplied with this product:
Properties & Usage
Materials Required but not Supplied
80% Ethanol (freshly prepared)Nuclease-free Water
DNA LoBind Tubes (Eppendorf® #022431021)
Magnetic rack or plate (e.g., NEBNext® Magnetic Separation Rack (NEB #S1515S), Alpaqua ® 96S Super Magnet Plate (#A001322), or equivalent)
Thermocycler
Vortex
Microcentrifuge
SPRIselect Reagent Kit (Beckman Coulter®, Inc. #B23317) or AMPure® XP
Beads (Beckman Coulter, Inc. #A63881)
Agilent® Bioanalyzer® or similar fragment analyzer and associated consumables
DNase RNase free PCR strip tubes (USA® Scientific 1402-1708)
Protocols, Manuals & Usage
Manuals
FAQs & Troubleshooting
FAQs
- How much PBS can be carried over from cell collection into the cDNA Synthesis and Amplification protocol?
- What cell types does the NEBNext Single Cell/Low Input cDNA Synthesis & Amplification Module support?
- Can I resuspend the cells in buffers/medium other than PBS before cell collection?
- Do the cells have to be sorted in to a specific reagent?
- Can frozen cells be used?
- Can cells be lysed using other cell lysis buffers?
- How long can the synthesized cDNA (prior to cDNA amplification) be stored for prior to amplification?
- What types of RNA are compatible?
- Does the input total RNA have to be purified?
- My total RNA sample is in a volume > 8 µl. Can I still use the module?
- Is the cDNA generated by the NEBNext Single Cell/Low Input cDNA Synthesis & Amplification protocol compatible with Nextera® XT from Illumina?
- How should the adaptor sequences be trimmed?
- Where can I find protocols for low-input RNA library prep for use with the following kits: NEBNext® Single Cell/Low Input RNA Library Prep Kit for Illumina (NEB #E6420), NEBNext® Single Cell/Low Input cDNA Synthesis & Amplification Module (NEB #E6421), and NEBNext® Single Cell Lysis Module (#E5530)?
Citations & Technical Literature
Citations
Additional Citations
Quality, Safety & Legal
Quality Assurance Statement
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.Specifications
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]Certificate Of Analysis
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]- E6421G_v0_10012047
- E6421L_v1_10012082
- E6421S_v1_10012068
- E6421G_v0_10018869
- E6421G_v0_10024240
- E6421G_v0_10025912
- E6421G_v0_10024863
- E6421L_v1_10030125
- E6421S_v1_10030123
- E6421G_v0_10034729
- E6421L_v1_10040875
- E6421S_v1_10040485
- E6421S_v1_10040471
- E6421L_v1_10047418
- E6421G_v0_10049104
- E6421S_v1_10049106
- E6421L_v1_10049296
- E6421S_v1_10041408
- E6421L_v1_10054437
- E6421S_v1_10056121
- E6421L_v1_10057573
- E6421S_v1_10057674
- E6421L_v1_10059064
- E6421S_v1_10059116
- E6421G_v0_10060360
- E6421L_v1_10060176
- E6421S_v1_10061547
- E6421L_v1_10062197
- E6421G_v0_10062974
- E6421S_v1_10070904
- E6421S_v1_10075509
- E6421S_v1_10075568
- E6421S_v1_10076823
- E6421G_v0_10078130
- E6421L_v1_10078127
- E6421S_v1_10078073
- E6421S_v1_10079842
- E6421S_v1_10068879
- E6421L_v1_10087116
- E6421L_v1_10092036
- E6421S_v1_10094261
- E6421L_v1_10095332
- E6421S_v1_10098611
- E6421L_v1_10104542
- E6421S_v1_10104997
- E6421L_v1_10106816
- E6421S_v1_10106966
- E6421G_v0_10108930
- E6421L_v1_10109763
- E6421S_v1_10106813
- E6421G_v0_10099384
- E6421L_v1_10099412
- E6421S_v1_10120750
- E6421S_v1_10099401
- E6421G_v0_10128238
- E6421L_v1_10128248
- E6421S_v1_10128246
- E6421S_v1_10134602
- E6421L_v1_10137081
- E6421L_v1_10141547
- E6421S_v1_10116885
- E6421L_v1_10151631
- E6421S_v1_10151570
- E6421S_v1_10136433
- E6421G_v0_10155824
- E6421L_v1_10136423
- E6421G_v0_10136407
- E6421S_v1_10159597
- E6421S_v1_10167098
- E6421L_v1_10169159
- E6421S_v1_10171863
- E6421L_v1_10159093
- E6421S_v1_10159105
- E6421G_v0_10159075
- E6421L_v1_10185786
- E6421S_v1_10185789
- E6421L_v1_10178979
- E6421G_v0_10178963
- E6421S_v1_10192293
- E6421S_v1_10178997
- E6421L_v1_10206559
- E6421S_v1_10206561
- E6421L_v1_10215530
- E6421G_v0_10193502
- E6421L_v1_10193515
- E6421L_v1_10213188
- E6421S_v1_10227343
- E6421L_v1_10242505
- E6421S_v1_10249045
- E6421L_v1_10231700
- E6421S_v1_10231706
- E6421L_v1_10248028
- E6421S_v1_10248050
- E6421L_v1_10275095
- E6421L_v1_10275093
Safety DataSheets
The following is a list of Safety Data Sheet (SDS) that apply to this product to help you use it safely.NEBNext® Single Cell RT Primer Mix
NEBNext® Single Cell RT Buffer
NEBNext® Template Switching Oligo
NEBNext® Single Cell RT Enzyme Mix
NEBNext® Single Cell cDNA PCR Master Mix
NEBNext® Single Cell cDNA PCR Primer
NEBNext® Cell Lysis Buffer
Murine RNase Inhibitor
NEBNext® Bead Reconstitution Buffer
TE Buffer
Nuclease-free Water
Legal and Disclaimers
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
Licenses
This product is licensed for research and commercial use from Bio-Rad Laboratories, Inc., under U.S. Pat. Nos. 6,627,424, 7,541,170, 7,670,808, 7,666,645, and corresponding patents in other countries. No rights are granted for use of the product for Digital PCR or real-time PCR applications, with the exception of quantification in Next Generation Sequencing workflows.
For additional information or to inquire about commercial use, please contact busdev@neb.com.
Other Products You May Be Interested In
The supporting documents available for this product can be downloaded below.