Instant Sticky-end Ligase Master Mix
Product informationCode | Name | Size | Quantity | Price | |
---|---|---|---|---|---|
M0370S |
Instant Sticky-end Ligase Master Mix |
50 rxns ( 2 X ) | - | Unavailable in your region | |
M0370L |
Instant Sticky-end Ligase Master Mix |
250 rxns ( 2 X ) | - | Unavailable in your region |
Instant Sticky-end Ligase Master Mix
Product Introduction
Instant Sticky-end Ligase Master Mix will ligate these substrates:
dsDNA
Nicked DNA/RNA
Specifically formulated to rapidly ligate cohesive-end (2–4 bp) substrates and improve transformation, Instant Sticky-end Ligase Master Mix is a ready-to-use 2X solution of T4 DNA Ligase and a proprietary ligation enhancer in an optimized reaction buffer.
- No incubation time necessary to achieve ligation
- No thawing of the master mix is required as liquid state is maintained when stored at -20°C
- Simplified reaction setup with optimized ratio of enzyme and buffer components
- Ligations for subcloning can be carried out in small volumes with low DNA concentrations, allowing users to conserve precious DNA samples and directly transform many strains of chemically competent E. coli without dilution
- Other T4 DNA Ligase products include Quick Ligation Kit, Salt-T4, Hi-T4, and Blunt/TA Ligase Master Mix
- Not sure which ligase to choose? Refer to our DNA and RNA Ligase Properties Chart or DNA Ligase Selection Chart
Catalog # | Size | Concentration |
---|---|---|
M0370S | 50.0 reactions | 2 X |
M0370L | 250.0 reactions | 2 X |
Featured Videos
View Video Library-
Quick Tips - Do I need a 5' phosphate for ligation?
-
NEBioCalculator® - Using the Ligation module
-
Quick Tips - Electroporation after ligation
-
Quick Tips - How do I calculate how much DNA to add to a ligation reaction?
-
Quick Tips - Troubleshooting problematic ligation reactions
-
Quick Tip - What is the ideal incubation temperature for ligation?
-
Quick Tip - When is a long incubation time necessary for ligation?
-
DNA Ligation
-
What are the best conditions for DNA ligation?
-
What molar ratios should I use for DNA Ligation?
-
Why do I need to add PEG to my DNA ligation?
-
Traditional Cloning Workflow
-
Overview of PCR Cloning
- Product Information
- Protocols, Manuals & Usage
- Tools & Resources
- FAQs & Troubleshooting
- Citations & Technical Literature
- Quality, Safety & Legal
- Other Products You May Be Interested In
Product Information
Description
Instant Sticky-end Ligase Master Mix is a ready-to-use 2X solution of T4 DNA ligase and a proprietary ligation enhancer in an optimized reaction buffer. Specifically formulated to rapidly ligate cohesive-end (2–4 bp) substrates and improve transformation, the mix simplifies reaction set-up and provides an optimized ratio of enzyme and buffer components. No thawing of the master mix is required as it maintains a liquid state during storage at -20°C* and no incubation time is necessary to achieve ligation efficiencies sufficient for successful sub-cloning of sticky-end substrates. Just add the master mix to DNA with compatible ends, mix and transform; thereby reducing the valuable time needed for routine ligations. Ligations for subcloning can be carried out in small volumes with low concentrations, allowing users to conserve precious DNA samples, and be used directly to transform many strains of chemically competent E. coli without dilution.* Freezers vary in their actual internal temperature. Our testing demonstrates that the master mix is liquid at -20°C. Freeze-thaw testing at -70°C has confirmed that the performance after 20 freeze/thaw cycles is close to the original mix.
Product Source
Purified from an E. coli strain containing a recombinant gene encoding T4 DNA Ligase.- This product is related to the following categories:
- DNA Ligases Products
- This product can be used in the following applications:
- Cloning Ligation,
- Fast Cloning: Accelerate your cloning workflows with reagents from NEB
Reagents Supplied
Reagents Supplied
The following reagents are supplied with this product:
NEB # | Component Name | Component # | Stored at (°C) | Amount | Concentration | |
---|---|---|---|---|---|---|
Properties & Usage
Heat Inactivation
NoApplication Features
- Vector construction
- Fragment assembly
- Library construction
Related Products
Companion Products
Product Notes
- DNA: Purified DNA for ligations can be dissolved in dH2O (Milli-Q® water or equivalent is preferable); TE or other dilute buffers also work well. For optimum ligation, the amount of vector DNA should be 20–100 ng and the insert should be added at a 3-fold molar excess. For ligation volumes greater than 10 μl, increase the volume of Instant Sticky-end Ligase Master Mix such that it remains 50% of the reaction. Insert: vector ratios between 2 and 6 are optimal for single insertions. Ratios below 2:1 result in lower ligation efficiency. Ratios above 6:1 promote multiple inserts. If you are unsure of your DNA concentrations, perform multiple ligations with varying ratios.
- Time and Temperature: Ligations performed using the Instant Sticky-end Ligase Master Mix are immediately ready to be used to transform E. coli. If it is necessary to incubate the reaction prior to transformation, performance is generally good between 4–25°C. Incubation can be performed for up to one hour at the chosen temperature without negatively impacting the performance of the mix. Blunt- and TA-ends can also be ligated by this mix but require a 5–15 minute incubation time to reach our internal performance standards. The "instant" ligation criteria were met with cohesive ends of 2–4 bp in length.
- Cells: Competent cells can vary by several logs in their competence. Perceived ligation efficiency directly correlates with the competence of the cells used for transformation. Always transform uncut vector as a control for comparison purposes.
- Electroporation: While electroporation can dramatically increase transformation efficiency, Instant Sticky-end Ligase Master Mix is not directly compatible with transformation by electroporation. It is necessary to reduce the PEG concentration. We recommend purification of the ligated DNA by spin column.
- Biology: Some DNA sequences are not easy to clone. Sequences that form structures, including inverted and tandem repeats, are selected against by E. coli. Some recombinant proteins are not well tolerated by E. coli and can result in poor transformation or small colonies.
Protocols, Manuals & Usage
Protocols
Usage & Guidelines
Application Notes
Tools & Resources
Selection Charts
Web Tools
FAQs & Troubleshooting
FAQs
- Do I need to transform the Instant Sticky-end Ligase Master Mix reactions immediately?
- Can the ligation reaction produced by the Instant Sticky-end Ligase Master Mix be directly used to transform electrocompetent cells?
- The recommended volume for an Instant Sticky-end Ligase Master Mix reaction is 10ul. I like to set-up my ligation reactions in a 20 ul volume. Can I scale-up the reaction?
- I routinely use more than 5 ul of my ligation reactions to transform 50 ul aliquots of competent cells. When I do this with the Instant Sticky-end Ligase Master Mix my transformation plates have very few colonies. What do you think is the problem?
- Can the Instant Sticky-end Ligase Master Mix be used for the ligation of blunt-end or single-base overhang fragments?
- My Instant Sticky-end Ligase Master Mix has frozen in my freezer. Is this a problem?
- The protocol for Instant Sticky-end Ligase Master Mix indicates thereaction should not be heat inactivated. How can I inactivate theligation activity?
Troubleshooting
Citations & Technical Literature
Citations
Additional Citations
Quality, Safety & Legal
Quality Assurance Statement
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.Specifications
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]Certificate Of Analysis
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]- M0370S_L_v1_0151710
- M0370S_L_v1_0161803
- M0370S_v1_10008066
- M0370L_v1_10008064
- M0370L_v1_10020317
- M0370L_v1_10026403
- M0370S_v1_10020318
- M0370S_v1_10035065
- M0370L_v1_10035067
- M0370L_v1_10048659
- M0370S_v1_10048657
- M0370L_v1_10058675
- M0370S_v1_10079384
- M0370L_v1_10095233
- M0370S_v1_10096785
- M0370L_v1_10109481
- M0370S_v1_10117912
- M0370S_v1_10134393
- M0370L_v1_10145046
- M0370L_v1_10164288
- M0370S_v1_10153908
- M0370L_v1_10179949
- M0370S_v1_10195895
- M0370S_v1_10206996
- M0370S_v1_10214129
- M0370L_v1_10226630
- M0370S_v1_10226653
- M0370L_v1_10245776
- M0370L_v1_10246823
- M0370S_v1_10245777
- M0370S_v1_10252856
- M0370L_v1_10252851
Safety DataSheets
The following is a list of Safety Data Sheet (SDS) that apply to this product to help you use it safely.Instant Sticky-end Ligase Master Mix
Legal and Disclaimers
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
Other Products You May Be Interested In
The supporting documents available for this product can be downloaded below.
Protocol
Transformation Protocol (M0370)
Protocol
Transformation Protocol (M0370)
Protocol
Transformation Protocol (M0370)
Protocol
Transformation Protocol (M0370)