NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat) with RNA Sample Purification Beads
Product informationCode | Name | Size | Quantity | Price | |
---|---|---|---|---|---|
E7755S |
NEBNext Globin & rRNA Depletion Kit (Human/Mouse/Rat) with Beads |
6 rxns | - | Unavailable in your region | |
E7755L |
NEBNext Globin & rRNA Depletion Kit (Human/Mouse/Rat) with Beads |
24 rxns | - | Unavailable in your region | |
E7755X |
NEBNext Globin & rRNA Depletion Kit (Human/Mouse/Rat) with Beads |
96 rxns | - | Unavailable in your region |
NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat) with RNA Sample Purification Beads
Product Introduction
Globin mRNA and rRNA are highly abundant in blood samples, and their efficient and specific removal is desirable in order to reveal the biological significance of less abundant transcripts.
The NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat) employs the NEBNext RNase H-based RNA depletion workflow to deplete globin mRNA, cytoplasmic rRNA and mitochondrial rRNA with human, mouse and rat samples, and is effective with intact and degraded RNA.
- Efficient, specific depletion of rRNA and globin mRNA (adult, fetal and embryonic)
- Suitable for low-quality or high-quality RNA
- Compatible with a broad range of input amounts: 10 ng - 1 μg
- Optional integration with poly(A) mRNA isolation workflows for removal of globin RNAs, rRNAs, and noncoding RNAs
- Fast workflow: 2 hours, with less than 10 minutes hands-on time
The kit is also available without RNAClean® beads.
Catalog # | Size | Concentration |
---|---|---|
E7755S | 6.0 reactions | |
E7755X | 96.0 reactions |
- Product Information
- Protocols, Manuals & Usage
- Tools & Resources
- FAQs & Troubleshooting
- Citations & Technical Literature
- Quality, Safety & Legal
- Other Products You May Be Interested In
Product Information
Description
The great majority of RNA in blood samples is comprised of cytoplasmic and mitochondrial ribosomal RNAs (rRNA) and globin mRNA. These highly abundant RNA species can conceal the biological significance of less abundant transcripts, and so their efficient and specific removal is desirable.
The NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat) employs the NEBNext RNase H-based RNA depletion workflow to deplete adult, embryonic and fetal globin mRNA (HBA1/2, HBB, HBD, HBM, HBG1/2, HBE1, HBQ1 and HBZ), cytoplasmic rRNA (5S, 5.8S, 18S, 28S, ITS and ETS) and mitochondrial rRNA (12S and 16S).
The kit is effective with human, mouse and rat total RNA preparations, both intact and degraded. The resulting depleted RNA is suitable for RNA-seq, random-primed cDNA synthesis, or other downstream RNA analysis.
This kit can also be used following poly(A) mRNA enrichment (e.g., using the NEBNext poly(A) mRNA Magnetic Isolation Module NEB #E7490), so that the final depleted RNA contains only mRNA of interest and no non-coding RNA.
The kit is also available without RNAClean® beads.
Features
- Efficient, specific depletion of rRNA and globin mRNA (adult, fetal and embryonic)
- Suitable for low-quality or high-quality RNA
- Compatible with a broad range of input amounts: 10 ng - 1 μg
- Optional integration with poly(A) mRNA isolation workflows for removal of globin RNAs, rRNAs, and noncoding RNAs
- Fast workflow: 2 hours, with less than 10 minutes hands-on time
- This product is related to the following categories:
- RNA Depletion & mRNA Enrichment Products,
- RNA Library Prep for Illumina,
- Epitranscriptome Analysis,
- Next Generation Sequencing Library Preparation Products,
Kit Components
Kit Components
The following reagents are supplied with this product:
NEB # | Component Name | Component # | Stored at (°C) | Amount | Concentration | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Properties & Usage
Materials Required but not Supplied
- Magnetic rack/stand such as the NEBNext Magnetic Separation Rack (NEB #S1515)
- 80% Ethanol (freshly prepared)
- Thermocycler
- Thin wall 200 µl PCR tubes
- Bioanalyzer®, TapeStation® (Agilent Technologies, Inc.) or similar fragment analyzer and consumables
Protocols, Manuals & Usage
Manuals
Tools & Resources
Web Tools
FAQs & Troubleshooting
FAQs
- What species can I use the NEBNext® Globin mRNA & rRNA Depletion Kit for? Will it work for other species?
- Which globin mRNAs and rRNAs are depleted with the NEBNext® Globin mRNA & rRNA Depletion Kit (Human/Mouse/Rat)?
- Can I use the NEBNext® Globin mRNA & rRNA Depletion Kit (Human/Mouse/Rat) with degraded RNA or fragmented RNA?
- What is the total RNA input I should use?
- Why must the RNA be free of DNA?
- What is the expected RNA yield recovered after globin mRNA and rRNA depletion?
- What is the percentage of globin mRNA and rRNA left after depletion?
- How can I determine if the globin mRNA and rRNA depletion was efficient?
- I am only interested in coding RNA. Can I use the NEBNext® Globin mRNA & rRNA Depletion Kit (Human/Mouse/Rat) to remove globin mRNA from previously enriched mRNA.
- Does the NEBNext® Globin mRNA & rRNA Depletion Kit (Human/Mouse/Rat) work for ribosomal footprinting or profiling applications?
- Can the enriched RNA resulting from the NEBNext depletion kit be used in long read sequencing applications?
Citations & Technical Literature
Citations
Additional Citations
Quality, Safety & Legal
Quality Assurance Statement
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.Specifications
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]Safety DataSheets
The following is a list of Safety Data Sheet (SDS) that apply to this product to help you use it safely.NEBNext® DNase I
NEBNext® Thermostable RNase H
NEBNext® Globin and rRNA Depletion Solution
RNase H Reaction Buffer
DNase I Reaction Buffer
Nuclease-free Water
NEBNext Probe Hybridization Buffer
NEBNext® RNA Sample Purification Beads
Legal and Disclaimers
Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.
New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.
Other Products You May Be Interested In
-
NEBNext® Ultra™ II Directional RNA Library Prep Kit for Illumina®
-
NEBNext® Ultra™ II Directional RNA Library Prep with Sample Purification Beads
-
NEBNext® Ultra™ II RNA Library Prep Kit for Illumina®
-
NEBNext® Ultra™ II RNA Library Prep with Sample Purification Beads
-
NEBNext® rRNA Depletion Kit (Human/Mouse/Rat)
-
NEBNext® rRNA Depletion Kit (Human/Mouse/Rat) with RNA Sample Purification Beads
-
NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)
The supporting documents available for this product can be downloaded below.