Invalid login

Your credentials are incorrect or you are trying to login with a non-existing webshop account. Our website shows product prices without login! Therefore webshop accounts that were only used to view prices have been deleted.

Please create a new account with your shipping and billing details if you would like to be able to order or view your discount.


Forgot your password?

Don't worry. Enter your username and we will send you a link to reset your password if an associated user is found.

Need help?

Have trouble resetting your password? Contact us and we will help you.

You've got mail

You will receive an e-mail containing a link to start the recovery procedure within minutes.


Change password

Change your password to something secure.

Success

Your password has been changed.


Password sent

You will receive an e-mail from us containing your new password in the coming minutes.

Please change your password to something memorable and secure upon logging in.


Amersham Typhoon NIR Plus

Product information

Amersham Typhoon NIR Plus


The NIR Plus laser scanner saves times by detecting up to three proteins, nucleic acids, or other biomolecules in a single blot. This scanner has 3 lasers to detect both NIR and green labeled antibodies.

Advantages

  • Time saving: visualize 2 target proteins, including normalization with a housekeeping gene or total lane protein, in a single blot
  • Versatility: image multifluorescent-labeled, and colorimetric samples on gels, membranes, microplates, culture dishes, and tissue sections*
  • Infrared and visible fluorescence imaging: use near-infrared (NIR) excitation to image IRDye™ and other infrared dyes; also has green channel
  • Accurate quantitation: detect signals from very low levels (pg) of protein and differences across a dynamic range with greater than 5 orders of magnitude
  • High resolution: resolve fine details in your sample with a pixel resolution of 10 µm
  • High sample throughput: maximize efficiency using 40 × 46 cm scanning area to simultaneously image up to 20 gels or blots (10 × 8 cm) or 9 multiwell plates
  • Ease of use: auto- and semi auto-scan functions, automatic filter recognition, and modular access make system well suited to multiuser environments
  • Open data format: output image files are compatible with other open platform analysis software, such as Image

* Depending on the sample format, additional accessories might be needed for the best performance.

Visible and infrared fluorescent gel imaging system

Amersham Typhoon NIR Plus is a versatile laser scanner for detecting up to three biomolecules in gels, blots, and other sample types. It has the same capabilities as the Typhoon 5 model, except it does not have red and blue fluorescent imaging or phosphor imaging functionalities. Typhoon NIR Plus supports the following imaging modes:

  • Near-infrared fluorescent imaging for NIR fluorescent Western blotting and other applications
  • Visible fluorescence imaging in green channel to support multiplex fluorescence imaging with NIR channels
  • Imaging of multiplex fluorescent Western blots, using ECL Plex and/or other fluorophore-labeled antibodies
  • Optical densitometry for quantitation of colorimetrically-stained samples (e.g., Coomassie™ blue; silver stain)†
  • Chemiluminescence imaging that does not require maximum sensitivity (dark scan function)

† Requires OD Plate AmTyphoon, 29191517

Near-infrared fluorescent imaging

This visible and infrared fluorescent gel imaging system is equipped with 2 NIR lasers that enable NIR fluorescent Western blotting. The two NIR lasers, optimized optics, and a new detector enable multiplex Western blotting with high sensitivity and wide dynamic range.

Multiplex fluorescence imaging applications

This Typhoon imager is optimized for multiplex fluorescence imaging with NIR and green channels. Typhoon NIR Plus provides precise quantitation of Western blotting, ECL Plex imaging, and nucleic acid detection.

Multiplex capabilities allow for simultaneous detection of three proteins in the same gel or blot; two proteins in the NIR channels, and one protein in the green visible channel. Detection can be performed with primary antibodies from up to three different species. Total lane normalization is accomplished through fluorescent reagents, such as Amersham QuickStain.

Upgrade paths

This Typhoon imager is fully upgradable to the Amersham Typhoon 5 model. Alternatively, red, blue, and phosphor imaging functionality can be added separately or in combination.

Specifications

Parameter Amersham Typhoon NIR Plus
Bit Depth 16
Depth 800 mm
Detection Modes Fluorescence, densitometry, and chemiluminescence (Dark scan)
Dynamic Range > 5 orders of magnitude
Frequency 50/60 Hz
Height 400 mm
Lasers SHG532, LD685, LD785
Operating Humidity 20% to 70%, RH (no dew condensation)
Pixel Size 10, 25, 50, 100 or 200 μm and a 1000 μm pre-scan
Power consumption Approx. 0.3 kVA
Scanning Area 40 x 46 cm
Standard Filters Cy3 Fltr 570BP20, IRshort Fltr 720BP20, IRlong Filtr 825BP30
Voltage AC100—240V~, Voltage variation±10%
Weight 93 kg
Width 900 mm
Model Typhoon NIR Plus

 